General 6/6Kv Power Cable

Basic Info

Model No.: YJV

Product Description






General 6/6Kv low voltage Cables of IEC Standards


High Voltage Power Cable OEM & ODM Factory Directly Sales




Low Voltage power cable for iec standardsIMG_2983Power Cable Manufacturer




power cable test lab









General Cables of IEC Standardspower cable structure











XLPE Insulated Cable


XLPE Insulated Power Cable,0.6-35KV,producing under IEC,BS,ASTM,DIN standard and OEM basis.





Al/Cu Conductor XLPE Insulated Thin/Thick steel armored PE Sheathed Power Cable.




Executive Standard:




It is manufacture under GB/T12706-2002 standard(The same as IEC60502).




Application:




It is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper Insulated Power Cable and in partial replace of PVC Insulated Power Cable.




Using features:




1. Rated voltage: Uo/U: 26/35kV, 21/35kV, 12/20 kV (24 kV), 8.7/10kV, 8.7/15kV, 6/6kV, 6/10kV.




2. No. of core: Single-core, Three-core.




3. The highest allowed operating temperature of conductor for long-term working is 90oC. In short-circuit (Max. Long-term is no more than 5 seconds). The highest temperature for conductor is no more than 250.




4. D.C Resistance of the conductor complies with the stipulations of GB/T3956-1997.




5. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated.




6. The cable is laid without horizontal drop limit. The Min. Bending radius of three-core cable should be no smaller than 12 times of cable outer diameter.




7. Working Frequency Voltage Test:.




For cable with Uo of 3.6kV or lower: 2.5Uo+2kV/5min without puncture.

For cable with Uo of 3.6kv~18kV: 3.5Uo/5min without puncture.

For cable with Uo of 21kV and 26 kV: 2.5Uo/30min without puncture.




8. Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73Uo for the cable.





This series includes:





Copper (aluminum) core, XLPE insulated and sheathed power cables.




Copper (aluminum) core, XLPE insulated, PE sheathed power cables.




Copper (aluminum) core, XLPE insulated, steel tape armoring PVC sheathed power cables.




Copper (aluminum) core, XLPE insulated, steel tape armoring, PE sheathed power cables.




Copper (aluminum) core, XLPE insulated, steel wire armoring, PVC sheathed power Cables.




Copper (aluminum) core, XLPE insulated, steel wire armoring, PE sheathed power cables




Rated voltage: 0.6/1kV, 3.6/6kV.




Number of cores: 1 to 6.




Relative manufacturing standards: IEC60505, BS, DIN.





Packing: Wooden drum, steel wooden drum.





Power Cable




-Conductor:

Solid or stranded copper




-Insulation:

Cross-linked polyethylene( XLPE or PVC)




-Circuit Identication:

The insulation shall be red, black




-Filler:

Polypropylene lament with lapped binding tape




-Inner Sheath:

Polyvinyl chloride (Black)




-Armor:

Galvanized Steel Wire




-Core-covering:

Binding tape




-Outer Sheath:

Polyvinyl chloride (Black)




-Application:

For use in ducts, trays and direct burial in ground. The cable is subject to immerse in water all the time.




-Standards / Testing Specications:

IEC 60502-1.




Installation




This cable can be installed in duct, tray or direct burial. It is recommended that the installation instructions indicated by the Local Electric Code, or any equivalent, be followed,so that the safeguarding of persons and the integrity of the product will not be affected by eciencies in the installation.




1. The products are mainly complying with IEC 60502 standard, also can be produced according to OEM requirements and other standards, such as BS standard, DIN standard, ASTM standard, etc.




Voltage grade is up to 35kv, cross-section area can be up to 400 sqmm (copper or aluminiun conductor). Conductor long-time operating temperature is 90 degrees. In short circuit, conductor highest temperature should be not more than 250 degrees.




2. Brief Construction:




Single core or multi-core


Copper or aluminium conductor


XLPE insulation


Copper tape or copper wire screen


Galvanized steel wire armored


PVC or PE sheath




Contact us if you need more details on General Power Cable. We are ready to answer your questions on packaging, logistics, certification or any other aspects about 6/6Kv Power Cable for Construction、General Cable for IEC Standards. If these products fail to match your need, please contact us and we would like to provide relevant information.

Product Categories : Medium Voltage Power Cable > 6/6kv Power Cables